Chart Recorders: General

If your instrument turns off, check the AC adapter connection to ensure that it is working properly.

To remove a chart, cut the tape evidence seal. Push in on cover and lift up, then proceed to remove the chart.

Response time is slower to preserve battery life.

If there is not power to the unit, check that the AC power adapter is plugged in and working correctly.

In this case, the probe should be dried out in normal, ambient conditions. The time required for the dry out varies based on temperature, relative humidity, and air flow.

Open the front door and remove the battery. Remove the four screws in the corners of the face plate. Carefully lift the face plate out of the case. Move the clock motor switch to the left for a 7 day rotation and to the right for a 24 hour rotation. (SKUs: PR8-1000 PR8100PB24S PR8100PB7S PR8200PB24S PR8200PB7S)

Chart Recorders: Temperature and Humidity

If the sensor was saturated, the unit may return to normal after a few hours in a dry environment. Does the environment where the unit is being used have a humidity above 95% or condensing? The humidity sensor has possibly been damaged and must be returned for service.

The display will show “HHH” or “LLL” if the temperature goes above or below the temperature measuring range of the MAIN or REMOTE unit.

Chart Recorders: Pressure

If the pen does not respond to pressure changes, there may be a clog in the capillary. The unit will need to be serviced by Dickson.

The display will show “HHH” or “LLL” if the temperature goes above or below the temperature measuring range of the MAIN or REMOTE unit.

Chart Recorders: Disposable

To start the unit, pull out the start tab.

To see if your unit is recording, check for gear movement after the start tab has been pulled.

To change from Celsius to Fahrenheit, press the C/F button on the back of the unit until the desired scale is displayed on the screen.

Chart Recorders (ESX, ET8)

Is the proper power adapter being used? It should be 6-Volts 700-800 milliamps. Make sure that dip switch # 7 is off; this switch controls the display. Make sure dip switch # 8 is off; this switch locks out the keypad. Remove all batteries and adapter, wait about 1-minute to let the unit discharge. The unit should respond when the adapter is plugged back in.

Chart Recorders (KT601, KT602, KT603, KT605, KT606, KT607, KT609, KT610, KT611)

Remove the battery and the AC power adapter. Wait about 1-minute to let the unit discharge. The unit should respond when the adapter is plugged back in. You may also remove the back panel of the recorder and make sure the power cord is plugged into PC board.

If there was a momentary power outage, the unit may not have had enough time to recognize this and switch to battery mode. The Chart Recorder may lock up or shut off in this situation. This situation may also occur if the unit is plugged into an outlet that shares the circuit with other machinery that has phase motors or compressors that cycle periodically. As these other machines cycle, they momentarily have a high current draw, therefore drawing from the unit.

Chart Recorders: (KT655, KT656, KT657, KT663, KT665, ET656, ET657)

Remove the battery and the AC power adapter. Wait about 1-minute to let the unit discharge. The unit should respond when the adapter is plugged back in. You may also remove the back panel of the recorder and make sure the power cord is plugged into PC board.

If there was a momentary power outage, the unit may not have had enough time to recognize this and switch to battery mode. The Chart Recorder may lock up or shut off in this situation. This situation may also occur if the unit is plugged into an outlet that shares the circuit with other machinery that has phase motors or compressors that cycle periodically. As these other machines cycle, they momentarily have a high current draw, therefore drawing from the unit.

Chart Recorders: TH601, TH602, TH603, TH605, TH606, TH607, TH609, TH610, TH611

Remove the battery and the AC power adapter. Wait about 1-minute to let the unit discharge. The unit should respond when the adapter is plugged back in. You may also remove the back panel of the recorder and make sure the power cord is plugged into PC board.

If there was a momentary power outage, the unit may not have had enough time to recognize this and switch to battery mode. The Chart Recorder may lock up or shut off in this situation. This situation may also occur if the unit is plugged into an outlet that shares the circuit with other machinery that has phase motors or compressors that cycle periodically.

Chart Recorders: (KTX, KTX-CE, KTXE, THDX, ET656, ET657)

If there was a momentary power outage, the unit may not have had enough time to recognize this and switch to battery mode. The Chart Recorder may lock up or shut off in this situation.

Is the proper power adapter being used? It should be 6-Volts 700-800 milliamps. Make sure that dip switch # 7 is off; this switch controls the display. Make sure dip switch # 8 is off; this switch locks out the keypad. Remove all batteries and adapter, wait about 1-minute to let the unit discharge. The unit should respond when the adapter is plugged back in.

Chart Recorders: 4" Recorders

The Time Indicator is the raised part directly to the right and slightly above the pen tip.

Use the back of a pencil to press the F/C button located on the back of the unit.

Please make sure the battery is inserted properly. The battery may be low or the unit may at a temperature below the specified range. (SKUs:SL4100 SL4350 SL490 VFC21 VFC70 VFC70D)

Chart Recorders: 6" Recorders

If your Chart Recorder is not moving, and seems to have been locked up, make sure that dip switch #1 is down and in the OFF position. The following diagram may help as well.

Chart Recorders: 8" Recorders

Use the “on/off” and “adjust up” buttons if the “on/off” and “adjust down” buttons don’t work. The Time Indicator is the raised part directly to the right and slightly above the pen tip. (SKUs: KT800 KT801 KT802 KT803 KT804 KT805 KT809 KT855 KT856 TH800 TH801 TH802 TH803 TH805 TH8P0 TH8P2 TH8P3 TH8P5).

Make sure the unit is in Fahrenheit when setting the alarm for the first time. Switch to Celsius and reset the alarm parameters. (SKUs: KT800 KT801 KT802 KT803 KT804 KT805 KT809 KT855 KT856 TH800 TH801 TH802 TH803 TH805 TH8P0 TH8P2 TH8P3 TH8P5)

 

 

No, there is no way to disable one of the channels. (SKUs:KT800 KT801 KT802 KT803 KT804 KT805 KT809 KT855 KT856 ET8 ET855)

Chart Recorders: Temperature and Humidity

If your chart does not have an Rh line it uses the same scale as the temperature.