This website uses cookies to help us give you the best experience when you visit.
By using this website you consent to our use of these cookies.
WFT22 - WiFi Vaccine Temperature Data Logger
SKU:WFT22
- Alarm Type Phone Call, SMS Text, Email, Audible
- Ambient Operating RH Conditions 0-95% RH non-condensing (Logger only)
- Ambient Operating Temperature Conditions -22.0 to 160.0F (-30.0 to 71.0C)
- Antenna Type External
- Approvals RoHS, FCC Part 15 Compliance, CE
- Battery Backup 4 AA Batteries
- Battery Life (Avg) 72 hours
- Calibration Options N100 , N300, N400, & N520
- Channels CH1: Temperature, CH2: Temperature
- Data Capacity 32,000 (16,000 per channel); Backup
- Digital Display Yes
- Dimensions 1.7 x 4.25 x 4.25in
- Download Type Wireless
- Enclosure Black; ABS Plastic Clam Shell
- IP Rating 21
- Included Accessories USB Cable, AC Adapter, 2-Probe with Glycol Bottle, 4 AA Batteries
- Mounting Options Free Standing or Wall Mount (With Keyhole)
- Note on Alarm Type Alarms can be created for scenarios where the readings are outside a given range, communication has been lost, or the batteries are low. All paid accounts are eligible to receive email and SMS text alarm notifications.
- PC Requirements Minimum of 2 GB RAM; Windows XP (with service pack 3) and Windows 7; 2 available USB ports
- Power Cord 6 ft
- Power Source 120 to 240 VAC, 12 VDC (INTL fittings available)
- Power Source Input AC 100-240 0.5V 60/50 Hz
- Power Source Output DC 9V, 1A
- Power Status Indicator Red/Green/Blue (RGB) LED
- Radio Frequency 2.4 GHZ
- Remote Sensor Length 6 ft (up to 3 extension cables can be added without sacrificing accuracy)
- Response Time 30 Seconds to 63% of Full Scale
- Sample Interval User Selectable from: 60 seconds, 90 seconds, 2 minutes, 5 minutes, 10 minutes, 30 minutes, 1 hour
- Software Options All DicksonOne Data Loggers must be connected to a DicksonOne subscription to function correctly.
- Storage Conditions -22.0 to 158.0F (-30.0 to 70.0C)
- Storage Conditions RH 0-95% RH non-condensing
- Temperature Accuracy +/-0.9F from -58.0 to 68.0F (+/-0.5C from -50.0 to 20.0C); +/-1.2F from 69.0 to 122.0F (+/-0.7C from 21.0 to 50.0C)
- Temperature Accuracy (Remainder of Range) +/-1.8F (+/-1C) from 123-158F (51-70C)
- Temperature Range -58.0 to 158.0F (-50.0 to 70.0C)
- Temperature Sensor Type Field Replaceable Thermistor hard wired to PBC, submersible tip sealed in leak-proof glycol bottle Glycol will freeze at -55F
- Unit Weight 3 lbs
- Units/Pkg 1
No longer available